How far a pergola beam can span depends on its size, its timber, the wind class and how much of the rafters it carries, so the answer comes from a span table. In Timber Queensland's pergola data sheet, a 190 x 45 mm treated pine beam spans 3,800 mm between posts with a 1,500 mm roof load width, and 2,700 mm with a 3,000 mm one.
Below is how to read a pergola span table, sample beam and rafter spans for treated pine and hardwood, posts and footings, Gold Coast wind and salt air, and approvals. The figures are from Timber Queensland's Technical Data Sheet 19 (revised March 2014), checked on 17 November 2026. They are a guide, not a design: your engineer or building certifier has the final word.
What are the parts of a timber pergola?
Posts, beams and rafters. The posts stand on footings. The beams run along the tops of the posts. The rafters sit across the beams, and on a pergola attached to the house, one end of each rafter sits on a ledger fixed to the house. Timber Queensland's diagram also shows knee braces, steel stirrups at the foot of each post, and battens on top when there is a roof.
The weight runs from the rafters, to the beams, to the posts, to the footings. So each part has its own table:
- rafter size and spacing set how far apart the beams can be
- beam size sets how far apart the posts can be
- post size depends on its height and the area of roof frame it holds up
Timber Queensland and WoodSolutions both cap rafter spacing at 900 mm. Timber Queensland's tables give 600 and 900 mm.
How do you read a pergola span table?
Pick the table for your wind class, find your timber and size, then read across to your load width or rafter spacing. Timber Queensland's beam tables use these terms:
- Roof load width is how wide a strip of rafters the beam holds up. In Timber Queensland's diagram, an outside beam carries half the rafter span plus the rafter overhang. A wider strip means a shorter beam span.
- Single or continuous. A single span beam sits on two posts. A continuous beam runs in one piece over three or more posts, so it spans further.
- Wind class. Tables marked L are for N1, N2, N3 and C1. Tables marked H are for N4 and C2. C3 is outside the sheet.
- Overhang. A beam, or an unnotched rafter, can overhang its last support by up to 25% of the span behind it.
Then check what the sheet assumes. Its sizes allow for a light roof of up to 10 kg per m2, now or added later, on a fairly flat skillion roof. For pitched roofs, bigger spans or other stress grades, it points to AS 1684, the Australian Standard for house framing.
How far can a pergola beam span?
In the low wind table, from 1,800 mm for a 140 x 45 mm treated pine beam carrying a wide strip of rafters, up to 6,700 mm for a 250 x 75 mm hardwood beam running over several posts. Here are sample rows. "2/" means two pieces side by side.
| Pergola beam (N1 to N3, C1) | Single span, 1,500 mm load width | Single span, 3,000 mm load width | Continuous, 1,500 mm load width | Continuous, 3,000 mm load width |
|---|---|---|---|---|
| Treated pine F7, 140 x 45 mm | 2,800 mm | 1,800 mm | 2,900 mm | 1,900 mm |
| Treated pine F7, 190 x 45 mm | 3,800 mm | 2,700 mm | 3,900 mm | 2,800 mm |
| Treated pine F7, 2/190 x 35 mm | 4,800 mm | 3,500 mm | 5,300 mm | 3,600 mm |
| Treated pine F7, 240 x 45 mm | 4,900 mm | 3,300 mm | 5,100 mm | 3,400 mm |
| Hardwood F14, 150 x 75 mm | 3,800 mm | 3,300 mm | 4,900 mm | 4,000 mm |
| Hardwood F14, 200 x 75 mm | 4,700 mm | 4,200 mm | 5,800 mm | 5,300 mm |
| Hardwood F14, 250 x 75 mm | 5,400 mm | 4,900 mm | 6,700 mm | 6,100 mm |
Source: Timber Queensland Technical Data Sheet 19, Pergolas and Carports (revised March 2014), Table 2L, for seasoned treated pine F7 and unseasoned hardwood F14. The sheet also covers cypress, and wider load widths of 4,500 and 6,000 mm.
Notice how much load width matters. Doubling it from 1,500 to 3,000 mm cuts a 190 x 45 mm pine beam from 3,800 to 2,700 mm.
How far can pergola rafters span?
In treated pine at 600 mm spacing, from 2,200 mm for a 90 x 45 mm rafter up to 7,200 mm for a 240 x 45 mm one, as a single span. Rafter span is the distance between the beams, or between a beam and the ledger on the house.
| Pergola rafter (N1 to N3, C1) | Single span, 600 mm spacing | Single span, 900 mm spacing | Continuous, 600 mm spacing |
|---|---|---|---|
| Treated pine F7, 90 x 45 mm | 2,200 mm | 2,000 mm | 2,700 mm |
| Treated pine F7, 140 x 45 mm | 4,800 mm | 4,000 mm | 5,100 mm |
| Treated pine F7, 190 x 45 mm | 6,200 mm | 5,600 mm | 7,000 mm |
| Hardwood F14, 100 x 50 mm | 3,200 mm | 3,000 mm | 4,300 mm |
| Hardwood F14, 150 x 50 mm | 4,600 mm | 4,300 mm | 6,300 mm |
Source: Timber Queensland Technical Data Sheet 19 (revised March 2014), Table 5L.
Spacing rafters at 900 mm means fewer rafters but shorter spans. For notched rafters, the overhang limits come from AS 1684, not the sheet.
What changes for Gold Coast wind and salt air?
A higher wind class means shorter spans, and near the beach the steel fixings need more protection. Each block gets its own wind class, and our guide to wind ratings like N2 and N3 explains how. Timber Queensland's higher wind tables cut spans like this:
| Treated pine F7, single span | N1 to N3, C1 | N4, C2 |
|---|---|---|
| 190 x 45 mm beam, 1,500 mm load width | 3,800 mm | 3,000 mm |
| 240 x 45 mm beam, 3,000 mm load width | 3,300 mm | 2,700 mm |
| 190 x 45 mm rafter, 900 mm spacing | 5,600 mm | 4,500 mm |
Source: Timber Queensland Technical Data Sheet 19 (revised March 2014), Tables 2L, 2H, 5L and 5H.
Wind also lifts a pergola. Timber Queensland says fixing one to the house fascia adds uplift to the house roof, so the wall, roof frame and tie-downs must be checked first.
For salt air, the QBCC's corrosion article puts the sea spray zone within 1 km of a surf coast, and counts pergolas as exposed. It says standard Z275 galvanised brackets suit inside use only. Brackets outdoors, or touching treated timber, need more protection, such as stainless steel. Timber Queensland asks for hot dipped galvanised or stainless steel fixings on every pergola.
What size posts and footings does a pergola need?
A 90 x 90 mm treated pine post can stand up to 4,100 mm tall when it holds up 10 m2 of roof frame. Timber Queensland sizes posts by height and by the roof area each one supports: out to any overhang, and halfway to the next support each way.
| Post | 5 m2 roof area | 10 m2 roof area | 20 m2 roof area |
|---|---|---|---|
| Treated pine F7, 70 x 70 mm | 3,500 mm | 2,500 mm | Not suitable |
| Treated pine F7, 90 x 90 mm | 4,800 mm | 4,100 mm | 2,900 mm |
| Hardwood F14, 100 x 100 mm | 4,800 mm | 4,800 mm | 4,200 mm |
Source: Timber Queensland Technical Data Sheet 19 (revised March 2014), Table 1, maximum post height.
Timber Queensland prefers posts in hot dipped galvanised stirrups set in concrete, with 75 mm clear between the concrete and the post for termite checks. It says footings should be designed by an engineer for both bearing and uplift. Framing in the weather should be H3 treated pine, Class 1 or 2 hardwood, or cypress, and posts in the ground H5. Our guide to H3 and H4 treated pine explains the classes.
Bracing stops the frame swaying. A freestanding pergola needs crossed diagonal braces between posts in both directions. An attached one can use crossed braces under the rafters or between posts, or a pair of knee braces.
Do these tables work for a pergola with a roof?
Only for a light one. Timber Queensland's sheet stops at roofing of 10 kg per m2 on a fairly flat skillion roof. Dindas, for example, sizes roofed verandah beams for roofs of 40 and 90 kg per m2, four to nine times that (our sum). A roofed pergola or patio with a heavier roof needs those other tables or an engineer.
A roof changes the approval too. The City of Gold Coast says an unroofed pergola under 2.4 metres high (2.1 metres mean height), 10 m2 and 5.0 metres long needs no building approval, but a roofed patio usually does. Our guide to council approval on the Gold Coast has the detail, and our guide to pergola costs on the Gold Coast covers prices and timber choices.
We build open timber pergolas across the Gold Coast, to the span tables or the engineer's design. We do not build patio roofs. Brett holds QBCC licence 15316127. See our deck building page for the outdoor work we do.
Where do these figures come from?
Checked on 17 November 2026: Timber Queensland, Technical Data Sheet 19, Pergolas and Carports (revised March 2014, copy hosted by a timber yard), Tables 1, 2L, 2H, 5L and 5H and its notes on roofs, posts, footings, bracing and attaching to the house; WoodSolutions, Pergolas page (undated); Dindas Australia, LVL 13.2 Span Tables Design Guide (2025), verandah beams; the QBCC article on corrosion protection for joist hangers and other connectors (last reviewed 20 July 2020); and the City of Gold Coast page, Do your building works need approval (undated). The roof weight comparison is our sum. We will check these figures again every three months.
See our decks and patios work, or check what your job will cost.


