An LVL beam is an engineered timber beam made from thin layers of wood veneer glued together. It is stiffer and stronger than sawn pine of the same size, so it is used where a long span or a heavy load would need a very deep piece of solid timber.

The size you need comes from the maker's span table or an engineer, based on the span, the load and the site. Below is what LVL is, how it compares, common sizes, sample spans and when you need an engineer. These are published figures from LVL makers, checked on 10 November 2026. They are a guide, not a design for your home.

What is an LVL beam?

LVL stands for laminated veneer lumber. Thin sheets of veneer are glued into a long, solid section. Wesbeam says this gives more consistent properties than sawn timber, with less variation from piece to piece. Makers sell it in standard depths and widths, like sawn timber, and in long lengths.

LVL is graded by its stiffness. Wesbeam says its e-beam LVL is known in the trade as E13 or E13.2, after its average stiffness. Dindas lists the stiffness of its LVL 13.2 as 13,200 MPa.

Wesbeam lists these uses for its e-beam LVL:

  • floor beams and floor joists
  • rafters, roof beams, strutting beams and hanging beams
  • ceiling joists, verandah beams and wind beams
  • wall lintels and wall studs

In a renovation, you will often see LVL as the beam over a wide opening, such as a stacker door, or as the beam that takes the place of a wall that has been taken out. Our guide to what a lintel is explains how the beam over an opening works.

Is LVL better than solid timber or steel?

For long spans, LVL is stronger and stiffer than sawn pine of the same size. Here is how the published figures compare:

MaterialStiffnessBending strengthSource
MGP10 pine10,000 MPa17 MPaTimberlink
F7 pine7,900 MPa18 MPaTimberlink
Dindas LVL 13.213,200 MPa48 MPa (less for beams deeper than 95 mm)Dindas design guide, 2025

So LVL can span further at the same size, or do the same job in a smaller section. Wesbeam says its LVL is designed to span further and carry greater loads. Makers also make it in long lengths: Wesbeam sells e-beam up to 12.6 m, and Dindas up to 12 m. Our guide to what MGP10 is explains the pine grades in that table.

Steel beams are sized by an engineer too. Whether LVL or steel suits your job is the engineer's call. They weigh the span, the load, the depth you have room for and how the beam connects to the rest of the frame.

What sizes do LVL beams come in?

Most LVL is 35, 45 or 63 mm thick, in depths from 90 mm up to 400 or 450 mm. Sizes are written depth by thickness. Here is what two makers list:

Maker and productDepthsThicknessesLengths
Wesbeam e-beam90, 130, 150, 200, 240, 300, 360, 400, 450 mm35, 45, 63, 75 mmUp to 12.6 m
Dindas LVL 13.290, 130, 150, 170, 200, 240, 300, 360, 400 mm45, 63, 75 mmUp to 12 m

Not every depth comes in every thickness. Wesbeam makes its 75 mm thick beams only in 300 and 400 mm depths, for WA and SA only, and its 450 x 63 mm beam for SA only. It says maximum size and stock vary by state. Dindas makes its 75 mm thick LVL in 150, 300 and 400 mm depths.

Span tables also list two beams side by side, written as "2/300x45", for heavier loads.

How far can an LVL beam span?

It depends on the load. The same beam spans much further under a light roof than under a heavy one. Here are sample rows from the Dindas LVL span table for a lintel in a single storey wall (or the top storey), at a roof load width of 3,000 mm and rafters or trusses at 600 mm centres. Dindas uses a roof mass of 40 kg per m2 and 90 kg per m2 in its tables for sheet and tiled roofs.

Dindas LVL 13.2 lintelRoof mass 40 kg per m2Roof mass 90 kg per m2
150 x 45 mm2,400 mm1,900 mm
200 x 45 mm3,200 mm2,500 mm
240 x 45 mm3,600 mm3,000 mm
300 x 45 mm4,300 mm3,500 mm
360 x 45 mm4,900 mm4,000 mm (needs at least 45 mm bearing at each end)

Those are maximum single spans, for wind classes N1 to N4 and a 30 degree roof pitch. Our guide to wind ratings N1 to N4 explains what those classes mean. Roof load width is the width of roof that rests on that wall. Every one of those things changes the answer. A floor above, a point load from a post, or a wider roof load width means a different table.

How to read a maker's table:

  • Use the table for the exact product. Dindas says not to apply values from one LVL product or guide to another.
  • Find the table for your job. Dindas has separate tables for floor joists, floor bearers, lintels, verandah beams, rafters, hanging beams and more.
  • Match every condition: roof mass, load width, spacing and wind class.
  • Read the span for your size. Dindas says "N/A" means there is no value, and not to estimate one from the nearest entry.
  • Check the footnotes. Some spans need a longer bearing at each end.

Deck bearers have their own tables. See our guide to deck bearer span.

Can you use LVL outside?

Yes, if it is treated for outdoor use and kept off the ground. Wesbeam sells e-beam in internal and external treatments. Dindas says its LVL 13.2 is H3 treated for external jobs such as decks, pergolas and external framing.

H3 is the hazard class for timber outside and above the ground, wetted from time to time but able to dry out. WoodSolutions' guide to treatment classes lists decking, cladding and fascia as H3 uses. It says timber closer than 400 mm to the ground should go up to H4 or a Class 1 hardwood, and any structural timber in the ground needs H5 or a Class 1 hardwood. So an H3 LVL beam belongs up on posts or stirrups, well clear of the dirt.

Two more checks for outdoor beams:

  • The right table. Dindas has its own tables for verandah beams. Use the table for that job.
  • Fixings near the beach. The QBCC says the basic galvanised coating on steel fittings suits dry, indoor spots only. It calls anywhere within 1 km of a surf coast, or 100 m of a bay, the sea spray zone, where fittings need more, such as stainless steel.

Do you need an engineer to size an LVL beam?

Often, yes. A simple lintel or bearer that fits a maker's span table can be read straight off it, but anything outside the table's conditions needs an engineer. Dindas says its tables support member selection within the guide's assumptions and do not replace engineering advice.

You need an engineer when:

  • You are removing or cutting into a load-bearing wall. Read our guide on how to tell if a wall is load bearing. The beam that replaces it is engineered.
  • The beam carries a point load, such as a post or another beam landing on it.
  • The beam overhangs a support. Dindas says to consult its engineers for cantilevers.
  • The beam is notched or drilled outside what AS 1684 allows. Dindas says that goes to a timber engineer.
  • The job is outside the table: a wind class, roof mass, span or load it does not cover.

In Queensland, the QBCC says building work over $3,300 needs a licensed contractor, and building design needs a licence at any value. The City of Gold Coast says repairs are exempt from approval only if they do not affect the structure, so changing a structural beam usually needs building approval.

We frame openings, build decks and do renovations across the Gold Coast, and we build from the engineer's design. We do not size structural beams: the engineer or the maker's table does. Brett holds QBCC licence 15316127. See our carpentry page for the work we do.

Where do these figures come from?

Checked on 10 November 2026: Wesbeam, e-beam product page (undated, 2026 site); Dindas Australia, LVL span tables page and its LVL 13.2 Span Tables Design Guide (2025); Timberlink, Is F7 or MGP10 graded timber better for outdoor structures in Australia? (undated); WoodSolutions, Preservative treatments and use classes (undated); the QBCC article on corrosion protection for joist hangers and other connectors (20 July 2020) and its page on who must hold a licence (16 April 2026); and City of Gold Coast, Do your building works need approval (undated). We will check these figures again every three months.