Skip to content

Cavity Sliding Doors: Sizes and How They Fit a Wall

Door sizes, stud openings and fitting one to an old wall.

Brett FieldOwner, Field Carpentry8 min read
Living room opening onto a timber deck

A cavity sliding door hangs from a track inside a steel or timber frame built into the wall, so the wall needs a stud opening about twice the door's width. Hume Doors' Internal Systems brochure gives the Queensland sum: the door height plus 70 mm high, and two door widths plus 60 mm wide. For a 2,040 x 820 mm door, that is a 2,110 x 1,700 mm opening.

Below is how the unit sits in the wall, the opening each common door needs, wall thickness, what a cavity wall cannot hold, how one goes into an existing wall, and the pros and cons. Sizes come from cavity unit makers' install guides and product pages, checked on 17 November 2026. Always work from the install sheet for the exact unit you buy.

What is a cavity sliding door and how does it sit in the wall?

It is a normal internal door that slides into a pocket inside the wall instead of swinging open. The pocket is a ready-made frame called a cavity unit.

Corinthian's Platinum 4000 install guide lists the main parts: the cavity pocket, a head track with rollers, split jambs that form the pocket's opening, removable fillets (trim strips that unscrew), and a closing jamb on the other side. The unit stands in a gap in the wall framing. Plasterboard or other sheeting then goes over both faces, so the door disappears into the wall when it is open.

There are two common looks:

  • Flush jamb. The open door sits flush with the jamb.
  • Flush pull. The open door sticks out about 50 mm, Corinthian says, so you can grab it.

One thing to know early: the frame carries the door, not the house. Corinthian's guide says its cavity units are not load bearing. That matters if you want one in an existing wall (more below).

What stud opening does a cavity sliding door need?

About two door widths plus 60 mm wide, and the door height plus 70 mm high, using Hume's formula for its Evolution timber cavity unit in Queensland. The stud opening is the gap in the wall frame before any sheeting goes on.

Door (height x width)Stud opening height (Qld)Stud opening width (flush jamb)
2,040 x 620 mm2,110 mm1,300 mm
2,040 x 720 mm2,110 mm1,500 mm
2,040 x 770 mm2,110 mm1,600 mm
2,040 x 820 mm2,110 mm1,700 mm
2,040 x 870 mm2,110 mm1,800 mm
2,340 x 820 mm2,410 mm1,700 mm

The sizes are our sums from Hume's Internal Systems brochure (July 2022). Hume adds 80 mm to the height in NSW, Victoria, the ACT, SA and Tasmania. It also warns that the unit size is tight, so allow extra room for packing.

Hume's 2026 catalogue no longer prints the formula, and other makers use their own numbers. So treat the table as a guide for planning, and frame to the sheet that comes with your unit. Hinged door sizes in general are in our guide to standard door sizes in Australia.

What size cavity sliding doors can you get?

Standard units take doors up to about 2,100 to 2,400 mm high, and the frame has to match the thickness of the wall. Here is what three makers list:

UnitWall framingLargest doorDoor weight limit
CS SlimSlider70 mm2,100 x 920 mmNot stated
CS SpaceMaker90 mm2,100 x 1,000 mmNot stated
CS MidWay90 mm2,400 x 1,200 mmNot stated
Corinthian Slimline 5000 (timber)90 or 100 mm2,340 x 920 mm80 kg
Corinthian Platinum 7000 (steel)90 mm2,340 x 1,200 mm80 kg
Hume Evolution timber or steelNot stated35 mm thick internal doors70 kg

So a 70 mm wall needs a slim unit made for it. Most of the units above are built for 90 mm framing. CS says most of its systems take doors 35 to 38 mm thick, and its standard stock size is 2,040 x 820 mm.

Weight matters too, so check your door against the unit's limit before you order. Our guide to hollow core vs solid core doors has door weights.

What can't go in a cavity sliding door wall?

Anything that pokes into the pocket. The door needs that space clear, so the wall over the pocket cannot hold the usual pipes, switches or long screws.

ItemWhat the maker says
PipesCS: plumbing cannot run in the pocket. Run it somewhere else, or build a false wall beside the pocket.
Light switches and power pointsRangerbuilt makes a cavity switch unit for 70 mm and 90 to 100 mm frames. A licensed electrician fits it and runs the wiring before the wall is sheeted.
Long screws for shelves, hooks or a TVCorinthian: screws must not stick out into the pocket.
Towel rails and grab railsCS: a full ply panel in the frame can take the place of noggings for these.
Wall tilesCorinthian Platinum 7000: tiles up to 10 mm thick or 50 kg/m2, on a substrate at least 9 mm thick, screwed every 200 mm. CS: up to 50 kg/m2 as tested, with 17 mm plywood for heavy tiles.

Plan this before the wall goes up. Moving a switch later means opening the wall again.

Can you fit a cavity sliding door into an existing wall?

Yes, if the wall is long enough, any pipes and wires can be moved, and the opening can be supported. It is a bigger job than a new wall because the wall has to be opened up and closed again. In plain steps:

  1. Check the wall. The cavity unit carries no load, so if the wall holds up the roof or a floor, the opening needs proper support. Our guide to telling if a wall is load bearing explains the signs. An engineer or certifier has the final word for your house.
  2. Check the length. You need a clear run of wall as wide as the stud opening: 1,700 mm for an 820 mm door, by Hume's sum.
  3. Check for asbestos. Asbestos Queensland says a house built before 1990 has a good chance of containing it, including wall sheeting in dry rooms. Its advice for renovators is to treat a material as asbestos until a lab has tested it.
  4. Open the wall. The sheeting comes off over the opening on both sides. An electrician moves any switches or wires, and a plumber moves any pipes.
  5. Frame the opening to the maker's stud opening, with a new head across the top and room for packing.
  6. Fit the unit. Corinthian says to stand it in the opening, plumb it, pack and fix the back of the pocket with at least three fixings, and fix the base to the floor.
  7. Sheet the wall. Leave the maker's temporary spacers in until the sheeting is done. Corinthian says taking them out early voids the warranty.
  8. Hang the door. Corinthian's Platinum 4000 leaves 5 to 22 mm under the door. Then the jambs, architraves and paint go on.

Prices for a new wall and a retrofit are in our sliding door installation cost guide.

What are the pros and cons of a cavity sliding door?

The big win is space: the door needs no room to swing. The main trade-off is a wall you cannot fix much to over the pocket.

  • Space. The door slides into the wall, so the floor a hinged door would sweep is free for a vanity, a bench or furniture.
  • Access. CS says its cavity doors without its SofStop closer meet AS 1428.1, the access standard, with an opening force under 20 N and an 850 mm clear opening.
  • Sound. For rooms that need sound control, CS sells a SoundStop unit with an acoustic door rated up to Rw 42.
  • Locks and privacy. For a bathroom, CS's FAQ gives the example of a privacy snib on one side and an emergency release on the other.
  • Soft close. Hume, Corinthian and CS all sell soft close kits that stop the door slamming.
  • The wall. No pipes, switches or long screws over the pocket, as set out above.

A barn door hangs on the face of the wall instead, and a sliding glass door is an outside door with its own frame. Neither needs a pocket.

What is different about cavity sliders on the Gold Coast?

Some units come with fewer options here, and tiled walls, termites and moisture all need care.

  • Queensland options. Hume's flush pull is not sold in Queensland, and its closing jamb is not included here. Corinthian's Slimline 5000 is only offered in Queensland for 2,040 mm doors and 90 mm studs.
  • Tiled walls. A QBCC building alert on cavity sliding doors says audits found faults with cavity frames in fully tiled walls. Sheeting must follow the maker's install rules, fixings must go in at the stated spacing, and sheet joins must line up with the frame rails.
  • Termites and moisture. Hume says its Evolution steel unit is galvanised and termite resistant. Corinthian says a new door, including its top and bottom edges, needs two coats of paint or sealer to stop it soaking up moisture and warping. Do that before the door goes into the pocket.
  • Licence. The QBCC carpentry licence covers installing doors, including the framing. Work valued over $3,300 must be done by a contractor with a QBCC licence.

We fit cavity sliders and barn doors across the Gold Coast, and frame new openings. Brett has more than 25 years on the tools and holds QBCC licence 15316127. See our sliding doors page for the work we do.

Where do these figures come from?

Checked on 17 November 2026: Hume Doors, Internal Systems brochure (July 2022, version 1.0) and catalogue (2026, version 1.0); Corinthian Doors, cavity units page (undated, 2026 site), Platinum 4000 cavity install instructions (drawings dated April 2021) and door installation guide (3 September 2024); CS Cavity Sliders, standard cavity sliders, FAQ, cavity solutions and wet area pages (all undated, 2026 site); Rangerbuilt, cavity switch unit page and install guidelines (undated); the QBCC building alert on cavity sliding doors (reviewed 4 April 2025), carpentry licence page (30 August 2021) and when you need a licence (11 August 2021); and Asbestos Queensland, Homeowners: look, check and prepare (undated). Sizes are makers' figures, not building rules. We will check these figures again every three months.

See our carpentry work, or check what your job will cost.

Filed under Carpentry

Free price check

What will your job cost?

3 quick questions, then a Gold Coast price range. No details needed.

Question 1 of 3

What's the job?
Brett Field Free price check