How far a floor joist can span depends on its size, the timber, how far apart the joists are and how heavy the floor is, so the answer comes from a maker's span table. In Hyne Timber's free table, a 190 x 45 mm MGP10 pine joist at 450 mm spacing spans 3,600 mm as a single span, and 4,400 mm when it runs unbroken over a middle support.
Below is how to read the tables, sample spans for MGP10 pine and LVL, joist spacing, tiled floors, and when you need an engineer or approval in Queensland. These are published figures from makers' guides, checked on 17 November 2026. They are a guide, not a design for your floor.
How do you read a floor joist span table?
Find your joist size in the left column, then read across to your spacing and span type. The number is the longest span allowed, in millimetres. Four terms do most of the work:
- Span is the distance between the supports the joist sits on, such as bearers or walls, measured centre to centre.
- Spacing is the gap from one joist to the next, centre to centre, usually 450 or 600 mm.
- Single or continuous. A single span joist sits on two supports. A continuous joist is one unbroken piece over three or more supports, so it spans further. Hyne and Dindas only count it as continuous if the shorter span is at least 75% of the longer one. A joist cut or joined over the middle support is single span.
- Floor load. Hyne's and Dindas's tables are for a normal home: a live load (people and furniture) of 1.5 kPa and a 1.8 kN point load. Hyne assumes particleboard flooring at 30 kg per m2. Dindas assumes the whole floor weighs 40 kg per m2.
Read the notes under each table too. Both are for wind class N3, and Hyne's is for timber inside the house. If your floor falls outside the notes, the table does not apply.
How far can an MGP10 pine floor joist span?
At 450 mm spacing, from 1,500 mm for a 90 x 45 mm joist up to 4,800 mm for a 240 x 45 mm joist, as a single span. These rows are from Hyne's free span tables, for its T3 Green MGP10 pine. Hyne only gives 450 mm spacing, so the 600 mm column comes from an older industry sheet.
| MGP10 pine joist | Single span, 450 mm spacing | Continuous, 450 mm spacing | Single span, 600 mm spacing |
|---|---|---|---|
| 90 x 45 mm | 1,500 mm | 1,800 mm | 1,200 mm |
| 140 x 45 mm | 2,600 mm | 3,000 mm | 2,400 mm |
| 190 x 45 mm | 3,600 mm | 4,400 mm | 3,300 mm |
| 240 x 45 mm | 4,800 mm | 5,200 mm | 4,300 mm |
Sources: 450 mm columns, Hyne Floor Joist Span Table (version 4), particleboard flooring, wind class N3, timber kept dry. 600 mm column, Timber Development Association internal floor joist sheet (June 2007), built on the 2006 edition of AS 1684, floor up to 40 kg per m2. Its 450 mm single spans for these sizes match Hyne's.
Hyne also lists 35 mm thick joists, which span less: 3,300 mm for a 190 x 35 mm joist. Our guide to MGP10 timber explains the stress grade.
What about hardwood? We could not find a free, current F17 hardwood floor joist table from a maker. Those spans are in AS 1684.2 N3 Supplement 8, which Standards Australia sells, so we have left hardwood out rather than guess.
How far can an LVL floor joist span?
In the rows below, from 2,500 mm for a 130 x 45 mm joist up to 7,600 mm for a 360 x 45 mm joist over a middle support. LVL is made from thin timber veneers glued together. These rows are from the Dindas LVL 13.2 span tables.
| Dindas LVL 13.2 floor joist | Single span, 450 mm spacing | Single span, 600 mm spacing | Continuous, 450 mm spacing | Continuous, 600 mm spacing |
|---|---|---|---|---|
| 130 x 45 mm | 2,600 mm | 2,500 mm | 3,100 mm | 2,900 mm |
| 150 x 45 mm | 3,100 mm | 2,900 mm | 3,700 mm | 3,400 mm |
| 200 x 45 mm | 4,300 mm | 4,000 mm | 4,900 mm | 4,500 mm |
| 240 x 45 mm | 5,100 mm | 4,700 mm | 5,600 mm | 5,200 mm |
| 300 x 45 mm | 6,000 mm | 5,600 mm | 6,600 mm | 6,100 mm |
| 360 x 45 mm | 6,900 mm | 6,400 mm | 7,600 mm | 7,000 mm |
Source: Dindas LVL 13.2 Span Tables Design Guide (2025), floor joists carrying floor loads only, floor weight 40 kg per m2, sag limit 15 mm, wind class N3. Joists need at least 35 mm of bearing at the ends and 63 mm over a middle support.
The tables assume a structural sheet floor glued and screwed to the joists. Thicker joists span a little further: a 240 x 63 mm joist reaches 5,500 mm single span at 450 mm. Our guide to LVL beam sizes explains LVL itself.
How far apart should floor joists be?
Usually 450 or 600 mm, and the flooring decides which. WoodSolutions' guide to timber building systems says 300 to 600 mm is common. Then each floor sets its own limit:
- Timber strip flooring. In WoodSolutions' flooring guide, 19 mm boards in most species and grades need joists at 450 mm. Only select grade hardwood, joined over the joists, is allowed at 600 mm.
- Particleboard sheets. Structaflor says 19 mm sheets suit joists at 450 mm, and 22 mm sheets suit 600 mm.
- Fibre cement under tiles. James Hardie allows joists at up to 450 mm under its 19 mm Secura flooring and 600 mm under its 22 mm sheet, in homes.
Closer joists also span further. In the Dindas table, a 240 x 45 mm joist spans 5,100 mm at 450 mm spacing but 4,700 mm at 600 mm. Decks have their own rules, in our guide to deck joist spacing.
WoodSolutions also says a secret nailed timber floor needs seasoned joists (or cypress). If the joists shrink away from the boards, the boards move and squeak, a problem our guide to fixing squeaky floorboards covers.
What changes for a tiled or heavy floor?
A heavier floor, or one that must sag less, needs bigger or closer joists. A tile base is heavy on its own: James Hardie's 19 mm Secura sheet weighs 41 kg for a 1,800 x 900 mm sheet. That is about 25 kg per m2 (our sum), before tiles or adhesive.
Dindas gives tables for two floor weights, 40 and 65 kg per m2, and five sag limits, from 15 mm down to 6 mm. A smaller limit means a stiffer floor. Here is what that does to single spans at 450 mm spacing:
| Dindas LVL 13.2 joist | 40 kg per m2, 15 mm sag | 40 kg per m2, 6 mm sag | 65 kg per m2, 9 mm sag | 65 kg per m2, 6 mm sag |
|---|---|---|---|---|
| 200 x 45 mm | 4,300 mm | 3,600 mm | 3,700 mm | 3,400 mm |
| 240 x 45 mm | 5,100 mm | 4,100 mm | 4,300 mm | 3,900 mm |
| 300 x 45 mm | 6,000 mm | 4,800 mm | 5,000 mm | 4,500 mm |
Source: Dindas LVL 13.2 guide (2025), floor joists, single span, 450 mm spacing, wind class N3.
So a 240 x 45 mm joist that spans 5,100 mm under a light floor drops to 3,900 mm under a heavy, stiff one. Hyne says it in short: if you need less sag, consider the next size up. Which weight and sag limit suit your tiles is the engineer's call.
Heavy point loads are different again. WoodSolutions says large concentrated loads often need extra members or a support right under the load.
How deep does a floor joist need to be?
Deep enough for your span in the table, and depth does more than thickness. In Hyne's MGP10 table at 450 mm, going from 140 to 190 mm deep adds 1,000 mm of single span, and 190 to 240 mm adds 1,200 mm (our sums). In the Dindas table, going from 45 to 63 mm thick adds only 400 mm to a 240 mm deep joist.
For a first guess, WoodSolutions uses a span to depth ratio of 17 to 1 for joist floors, so a 4 m span needs about a 235 mm deep joist (our sum). It adds that past 5 or 6 m, sag and bounce usually set the size, and engineered timber products are likely to be more efficient. The span table still gives the real size.
The joists sit on bearers, which have their own tables. Hyne has a free floor bearer table, and Dindas has bearer tables for floor loads and for walls above.
Do you need an engineer or approval to change floor joists?
Usually, yes. Floor joists are structure.
- Notches and holes. Dindas says notches, cuts and holes must follow AS 1684.2 Clause 4.1.6, and anything beyond that goes to an experienced timber engineer. Ask before a plumber or electrician cuts a joist.
- Approval. The City of Gold Coast says minor repairs that do not affect a building's structural or fire safety may not need approval. New or replaced joists affect the structure, so ask a building certifier first.
- Licence. The QBCC says building work over $3,300 needs a QBCC licence. Its carpentry class covers subfloor framing and timber and sheet flooring.
We do framing and repairs inside kitchen, bathroom and laundry renovations across the Gold Coast, including termite damage repairs, and we build to the span table or the engineer's design. We do not size joists ourselves. Brett holds QBCC licence 15316127. See our carpentry page.
Where do these figures come from?
Checked on 17 November 2026: Hyne Timber, Timber Span Tables page (1 May 2023) and Floor Joist Span Table, version 4 (August 2025 file); Dindas Australia, LVL span tables page and LVL 13.2 Span Tables Design Guide (2025); Timber Development Association (NSW), internal floor joist spans sheet (June 2007); WoodSolutions Technical Design Guide 9, Timber Flooring (revised March 2017) and Guide 46, Wood Construction Systems (September 2018); Borg, Structaflor flooring design manual (undated); James Hardie, Hardie Secura Flooring Installation Guide (September 2025); Standards Australia store, AS 1684.2 N3 Supplement 8 (June 2010, listed as current); City of Gold Coast, Do your building works need approval (undated); and the QBCC pages on when you need a licence (reviewed 11 August 2021) and the carpentry class (reviewed 30 August 2021). The depth, weight and ratio sums are ours. We will check these figures again every three months.
See our carpentry work, or check what your job will cost.