Skip to content

How Far Can a Rafter Span?

How rafter spans work, common sizes and what changes them.

Brett FieldOwner, Field Carpentry8 min read
Timber verandah

How far a rafter can span depends on its size, how far apart the rafters are, how heavy the roof is and the wind class, so the answer comes from a span table, not a rule of thumb. In Dindas Australia's free LVL 13.2 span table, a 200 x 45 mm rafter at 600 mm spacing spans up to 4,800 mm under a 40 kg per m2 roof, as a single span in wind class N1 to N4.

Below is how rafter span tables work, sample spans from a maker's table, where MGP10 pine spans are published, what changes the span, rafter spacing, roof pitch, rafters versus trusses, and who can do the work in Queensland. These are published figures from makers' guides, checked on 16 November 2026. They are a guide, not a design for your roof.

What is a rafter span table?

It is a maker's chart of the longest span each rafter size can cover between supports, under set conditions. Dindas describes span tables as charts of the maximum distance a member "can safely cover between supports", based on its size and load.

A rafter table is only true for its own conditions. The Dindas rafter table, for example, fixes all of these:

  • the product and grade (Dindas LVL 13.2)
  • the wind class (one table for N1 to N4, another for C1 to C3)
  • the roof mass (40 or 90 kg per m2 when a ceiling is attached)
  • the rafter spacing (600, 900 or 1,200 mm)
  • a roof pitch of 30 degrees
  • whether a ceiling is fixed under the rafters

Dindas measures rafter spans along the horizontal, not along the slope. It also splits single spans (two supports) from continuous spans (one rafter running over three or more supports). Our guide to LVL beam sizes explains how to read a maker's span table step by step.

How far can an LVL rafter span?

In the rows below, from 1.5 m for a small 90 x 45 mm rafter under a heavy roof, up to 6.6 m for a 300 x 45 mm rafter under a light roof. These are sample rows from the Dindas table for single span roof rafters with a ceiling attached, wind class N1 to N4.

Dindas LVL 13.2 rafter600 mm spacing, 40 kg per m2900 mm spacing, 40 kg per m2600 mm spacing, 90 kg per m2900 mm spacing, 90 kg per m2
90 x 45 mm2,200 mm2,000 mm1,700 mm1,500 mm
130 x 45 mm3,200 mm2,800 mm2,500 mm2,200 mm
150 x 45 mm3,700 mm3,200 mm2,900 mm2,500 mm
200 x 45 mm4,800 mm4,300 mm3,800 mm3,300 mm
240 x 45 mm5,600 mm5,100 mm4,500 mm4,000 mm
300 x 45 mm6,600 mm6,000 mm5,500 mm5,000 mm

Source: Dindas LVL 13.2 Span Tables Design Guide (2025), roof rafters with ceiling attached, maximum single spans, 30 degree pitch. Minimum end bearing 45 mm.

Continuous spans go further. The same 200 x 45 mm rafter at 600 mm spacing under 40 kg per m2 reaches 6,200 mm as a continuous span. Dindas only counts a rafter as continuous if the shorter span is at least 75% of the longer one. If not, treat each span as single.

How far can an MGP10 rafter span?

That depends on the table for your wind class, roof weight and spacing, and the MGP10 rafter tables sit in a paid standard. Standards Australia sells AS 1684.2 Supplement 4, the timber framing span tables for wind class N3 in seasoned softwood, stress grade MGP10. We do not copy those tables here.

What we found on the makers' own sites today:

  • Hyne publishes free span tables for floor joists, floor bearers, deck joists, deck bearers and upper lintels, but not rafters. Its framing brochure (September 2025) points to Hyne Design, an online tool that works out span tables for a project's own loads.
  • Dindas publishes free rafter tables, but for its LVL, not for pine. Dindas says not to apply values from one product or guide to another.

So do not read an MGP10 span off an LVL table. They are different products, and a table for one does not carry over to the other. Our guide to what MGP10 is explains the pine grades. For an MGP10 rafter, the size comes from the AS 1684 supplement for your wind class, the frame or truss designer, or an engineer.

What changes how far a rafter can span?

Six things, going by the conditions written on the Dindas tables:

  • Size. A deeper rafter spans further. In the Dindas table, going from 200 to 240 mm deep adds 800 mm of span at 600 mm spacing under 40 kg per m2.
  • Spacing. Rafters further apart each carry more roof, so they span less.
  • Roof weight. Tilling's SmartLVL 12 guide (2019) uses 40 kg per m2 for a sheet roof and 90 kg per m2 for a tile roof. Those are the same two weights in the Dindas table above, and in those rows the heavier roof cuts the span by about a fifth.
  • Ceiling or no ceiling. Dindas has a separate table for rafters without a ceiling attached, with no restraint along the bottom edge.
  • Wind class. Dindas splits its tables into N1 to N4 and C1 to C3. Our guide to wind ratings N1 to N4 explains how a site's class is set.
  • Single or continuous. A rafter running over a middle support spans further.

A heavier roof is not always the risk. The Queensland Reconstruction Authority (QRA) says sheet metal roofs are lighter than tile, so the uplift in wind is greater, and they need stronger tie-downs. If you swap tiles for metal, it says to have the whole roof structure assessed first.

How far apart are rafters spaced?

The makers' tables we checked are set out for 600, 900 and 1,200 mm. The Dindas rafter tables give spans for all three. Tilling's SmartLVL 12 guide assumes rafters or trusses at up to 600 mm for a tile roof and up to 900 mm for a sheet roof.

Spacing is a trade-off. Wider spacing means fewer rafters, but each one must be bigger or span less. The plans set the spacing, and the span table for that spacing sets the size.

The ceiling under the roof has a say too. Gyprock's Red Book 2 install guide (May 2020) allows ceiling framing at up to 600 mm apart for its 10 mm Supaceil board in wind classes N1 to N4, but only 450 mm for its 10 mm Gyprock Plus.

What is a standard roof pitch in Australia?

There is no single standard pitch. The lowest pitch you can use depends on the roof sheet or tile. Lysaght lists a minimum roof slope of 5 degrees for its CUSTOM ORB corrugated steel. For its KLIP-LOK 700 HI-STRENGTH sheet, the minimum is 1 degree for most versions, or 2 degrees for some, depending on the steel thickness.

Pitch matters for rafters too. The Dindas rafter tables are based on a 30 degree pitch, so a much flatter or steeper roof is outside those tables. If you want roof tiles, check the tile maker's minimum pitch before the frame is designed.

Rafters or trusses: what is the difference?

A rafter roof is framed piece by piece on site. A truss roof uses triangular frames made in a factory. The Australian Government's YourHome guide says roofs can use prefabricated trusses "or more rarely these days, conventional framing".

For a homeowner, the differences that matter:

  • Where it is made. YourHome says building today generally favours making trusses and wall frames off site. A rafter roof is cut and fixed on site, sized from span tables or by an engineer.
  • Changes later. Cutting into either one is structural work. Our guide to attic ladder installation covers what the truss rules say about cutting a truss.
  • Tie-downs. Either way, YourHome says bracing and tie-downs must be designed and installed to the building code and wind loading standards.

Can I use a span calculator, or do I need an engineer?

A calculator is only as good as the table behind it. If it does not name the maker, product, grade, wind class, roof weight and spacing, you cannot check its answer.

Use the maker's own table when your job fits every condition on it. Dindas says its span tables support member selection within the guide's assumptions and do not replace engineering advice. You need an engineer when:

  • the rafter overhangs its support (Dindas says to ask its engineers about cantilevers)
  • it will be notched or drilled beyond what AS 1684.2 allows
  • it carries a point load, such as a strut or a beam
  • your wind class, pitch, roof weight or span is outside the table

Who can replace rafters in Queensland?

A licensed contractor, for any job over $3,300. The QBCC says building work valued over $3,300 needs a QBCC licence. Its carpentry licence class covers building timber and steel wall framing and roof structures.

Approval is a separate question. The City of Gold Coast says roofing work that replaces more than 20% of the existing roof needs building approval. It says minor repairs that do not affect the structure may not need approval. Rafters are structure, so replacing them usually needs building approval.

We build deck frames and do the framing inside our kitchen, bathroom and laundry renovations across the Gold Coast, to the sizes on the plans or the engineer's design. We do not size rafters: the span table or the engineer does. Brett holds QBCC licence 15316127. See our carpentry page for the work we do.

Where do these figures come from?

Checked on 16 November 2026: Dindas Australia, LVL span tables page and its LVL 13.2 Span Tables Design Guide (2025); Tilling, SmartLVL 12 Framing guide (2019, edition 1); Hyne Timber, Common product span tables page (undated) and Framing Category Brochure (September 2025); Standards Australia store, AS 1684.2 N3 Supplement 4 (listed as current); Lysaght, CUSTOM ORB and KLIP-LOK 700 HI-STRENGTH product pages (undated); Gyprock, The Red Book 2 Residential Installation Guide (May 2020); YourHome (Australian Government), Lightweight framing (undated); Queensland Reconstruction Authority, Cyclone Resilient Building Guidance for Queensland Homes (December 2019); the QBCC pages on who must hold a licence (last reviewed 11 August 2021) and the carpentry licence class (last reviewed 30 August 2021); and City of Gold Coast, Do your building works need approval (undated). We will check these figures again every three months.

See our carpentry work, or check what your job will cost.

Filed under Carpentry

Free price check

What will your job cost?

3 quick questions, then a Gold Coast price range. No details needed.

Question 1 of 3

What's the job?
Brett Field Free price check